The Straight Block typically makes up 85% of the ICF wall assembly on most residential & commercial jobs. This block has six (6) strong full length injection molded plastic ties made from Polypropylene (PP) regrind resin that are well marked with the word “Fox Blocks” located on both sides of the block. These ties secure the two pieces of 1.5 PCF density modified Expanded Polystyrene (EPS) foam together that makes up each block type. The blocks are stacked tightly together and inter-locked end to end to the desired wall length. Once a single layer or course of ICF blocks is installed, horizontal reinforcing steel bars are inter-locked securely together in the ties of the blocks, then another course of Straight Blocks are placed firmly on top as the wall is built. To improve construction wall strength during installation, each course of blocks should have their end-joint connections staggered in a running bond method from the course adjacent to it.
- 2-5/8" EPS for consistent R-Value
- Large interlock for strength
- Rebar notches are designed to lap rebar on top of each other to ensure proper concrete placement
- Type 2 density
Insulation Type | Expanded Polystyrene Insulation |
---|---|
Country of Origin | Canada/United States |
Assembled Width (in) | 48 |
Assembled Height (in) | 16 |
Assembled Depth (in) | 13.25 |
Assembled Weight (lb) | 7.5 |
Application Type/Use | Foundation Wall |
Overview
The Straight Block typically makes up 85% of the ICF wall assembly on most residential & commercial jobs. This block has six (6) strong full length injection molded plastic ties made from Polypropylene (PP) regrind resin that are well marked with the word “Fox Blocks” located on both sides of the block. These ties secure the two pieces of 1.5 PCF density modified Expanded Polystyrene (EPS) foam together that makes up each block type. The blocks are stacked tightly together and inter-locked end to end to the desired wall length. Once a single layer or course of ICF blocks is installed, horizontal reinforcing steel bars are inter-locked securely together in the ties of the blocks, then another course of Straight Blocks are placed firmly on top as the wall is built. To improve construction wall strength during installation, each course of blocks should have their end-joint connections staggered in a running bond method from the course adjacent to it.
- 2-5/8" EPS for consistent R-Value
- Large interlock for strength
- Rebar notches are designed to lap rebar on top of each other to ensure proper concrete placement
- Type 2 density
Specifications
Insulation Type | Expanded Polystyrene Insulation |
---|---|
Country of Origin | Canada/United States |
Assembled Width (in) | 48 |
Assembled Height (in) | 16 |
Assembled Depth (in) | 13.25 |
Assembled Weight (lb) | 7.5 |
Application Type/Use | Foundation Wall |