40 Amp Hot Tub, Pool and Spa Package
UPC
785901448174
Online Sku
1585457
Model Number
CQOE240GFINM
$0.00
$304.99
Pay as low as
$12.71 /month
for
24 months
This amount does not include taxes, shipping and other fees.
Loadcentres offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO Load Centers enable the use of a full complement of accessories such as combination covers which are included her Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 18 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO Load Centers feature plated copper bus, providing superior performance and durability. This QO Load Center enclosure contains a enclosed main breaker and is rated at 4 A and 1 phase. This 3 wire system is a NEMA 3R enclosure and comes with ground fault protection A combination cover is supplied with this load center.
- 3 Wire 120/240Vac, 40 amp 2 Pole QO GFCI (Ground Fault Circuit Interrupter) factory installed in loadcentre
- Polymer, compact Type 3R outdoor enclosure will not rust
- Unique side hinged door for easy access
- Unique side hinged door for easy access
- Extended mounting bracket permits quick pilot hole drilling and Hole spacing for brick mortar joint mounting
Manufacturer's Warranty | Lifetime |
---|---|
Country of Origin | Mexico |
Assembled Width (in) | 6.61 |
Assembled Height (in) | 9.6 |
Assembled Depth (in) | 4.09 |
Assembled Weight (lb) | 2.4 |
Wire Size | 4 AWG to 25 kcmil |
Temperature Rating (C) | 40 |
GFCI | No |
Interrupt Rating | 1000 Kilo-Amp |
Voltage Rating | 120/240 Volt AC |
Amperage Rating | 40 Amp |
Terminal Connection | Lug |
Number of Poles | 2 |
Overview
Loadcentres offer premium features by allowing QO breakers, ground arc fault interrupters arc fault interrupters and surge arresters to be installed inside QO Load Centers enable the use of a full complement of accessories such as combination covers which are included her Systems can be single or three phase and have indoor and outdoor versions. Indoor enclosures are designed to rotate 18 degrees to accommodate top or bottom service entrance feed which saves expensive service cable. QO Load Centers feature plated copper bus, providing superior performance and durability. This QO Load Center enclosure contains a enclosed main breaker and is rated at 4 A and 1 phase. This 3 wire system is a NEMA 3R enclosure and comes with ground fault protection A combination cover is supplied with this load center.
- 3 Wire 120/240Vac, 40 amp 2 Pole QO GFCI (Ground Fault Circuit Interrupter) factory installed in loadcentre
- Polymer, compact Type 3R outdoor enclosure will not rust
- Unique side hinged door for easy access
- Unique side hinged door for easy access
- Extended mounting bracket permits quick pilot hole drilling and Hole spacing for brick mortar joint mounting
Specifications
Manufacturer's Warranty | Lifetime |
---|---|
Country of Origin | Mexico |
Assembled Width (in) | 6.61 |
Assembled Height (in) | 9.6 |
Assembled Depth (in) | 4.09 |
Assembled Weight (lb) | 2.4 |
Wire Size | 4 AWG to 25 kcmil |
Temperature Rating (C) | 40 |
GFCI | No |
Interrupt Rating | 1000 Kilo-Amp |
Voltage Rating | 120/240 Volt AC |
Amperage Rating | 40 Amp |
Terminal Connection | Lug |
Number of Poles | 2 |